From 1 - 10 / 21
  • Categories  

    A flow tower is installed on the watershed of Roujan as well as a meteorological station of the AgroClim service unit (INRAE). At these points a set of sensors are arranged in order to collect various meteorological variables such as wind speed, air humidity and temperature, global radiation or evapotranspiration. Just like the other measurements made on the basin by sensors, data acquisition units record the values which are transmitted several times a day to our servers at the INRAE centre in Montpellier or retrieved via Agroclim's webservice. R routines are then used to process these data and prepare them for integration into the HYSAE database of the LISAH, thus integrating them into the information system for OMERE. Through the OMERE data web portal, the address of which is given in this fact sheet, the data can be consulted and downloaded.

  • Categories  

    A meteorological station and a flow tower have been installed in the Kamech watershed. Through these two stations, a set of sensors is arranged to collect various meteorological variables. The meteorological station, installed in 1998, is equipped with sensors that are placed two meters above the ground. These sensors allow the acquisition of global radiation, wind speed and direction, air temperature and humidity, atmospheric pressure. The instruments used are: pyranometer, anemometer (A100R, vector), wind vane (W200P), thermohygrometer (HPM45C, vaisala), barometer (CS100, Setra). The flow tower or micro-meteorological station, installed in 2010, is equipped with sensors installed at 10 meters from the ground, allows to measure the real evapotranspiration (ETR) by the turbulent covariance method. This method is based on high frequency measurements (10 to 20 measurements per second) of vertical wind speed, air temperature and air humidity. The instruments used are: sonic anemometer (CSAT3, Campbell Sc), icor 7500, air temperature and humidity (HMP45, vaisala). Additional sensors measuring temperature, relative humidity and speed are installed at 2 m height from the ground allowing to have a second point of measurement of the meteorological variables on the BV. A data acquisition system calculates and stores the average values over 30-minute time intervals. The data are collected by the staff of INRGREF of Tunis. They are processed, prepared in the format of integration in the database HYSAE of LISAH to be integrated into the information system of OMERE Through the OMERE data web portal, the address of which is given in this fact sheet, the data can be consulted and downloaded.

  • Categories  

    The rainfall of the Roujan (Hérault) catchment area has been acquired since 1992 through various measuring points on which sensors are positioned on a long-term and continuous basis. The data from these sensors are directly recorded on servers in Montpellier through remote transmission. Verification treatments and possible corrections are applied before the data sets are integrated into the HYSAE database. Through the OMERE data portal accessible from this sheet, the data can be downloaded from an interactive map. In addition to these raw data rainfall records, a so-called "synthetic" time serie is elaborated to provide a complete and uninterrupted chronicle of rainfall data representative for the catchment area.

  • Categories  

    The physico-chemical parameters measured in the Kamech basin and accessible via the data portal concern the electrical conductivity of the water.

  • Categories  

    Runoff and stream flow discharge have been monitored since 1994 at the outlet of the Kamech catchment, and since 2005 at four sub-catchment hydrological stations. Automatic sensors continuously collected and transmitted water level time series to servers in Montpellier (France). Verification and correction processes on the raw data, as well as the generation of elaborated data (e.g. calculation of runoff, discharge from water levels, modification of time steps, etc) are applied before integration of the data sets into the HYSAE database. The time series can be downloaded from an interactive map through the OMERE data portal accessible from this page.

  • Categories  

    Runoff and stream flow discharge monitoring in the Roujan catchment area (Hérault) is operational since 1992 at catchment and sub-catchments hydrological stations on which automatic sensors records water level time series on a long-term and continuous basis. The data from these sensors are collected and instantaneously transmitted to servers in Montpellier. Verification and correction processes on the raw data, as well as the generation of elaborated data (e.g. calculation of flows from water heights or modification of time steps) are applied before integration of the data sets into the HYSAE database. The water level and discharge time series can be downloaded from an interactive map through the OMERE data portal accessible from this page.

  • Regular sampling of surface water, rainwater or groundwater is carried out in the Roujan catchment area. These samples are sampled and analysed in order to assess the content of trace metals in the waters of the basin.

  • Categories  

    Pesticide contents are determined on the suspended matter extracted by filtration (0,7µm) in runoff water. Contents allow quantification of particula transport of pesticides and allow too compare it to solute transport.

  • Categories  

    water samples ( rain, runoff, underground water) are carried in icebox and frozen. ( FILTRATION ? ). Samples are analyzed by a dedicated laboratory, that quantify a set of parameters including from 1 to 430 pesticide active ingredients and their metabolites.

  • Categories  

    Water sampling in rain, runoff and undergroundwater are performed on the fields and send to a specialized laboratory to quantify major elements contents (Ca, Mg, Na, K, SO4, PO4, HCO3, NO3) ( FILTRATION ???. PH ??? ? EC, ???)